INTRODUCTION

The Database Versions Page (Figure 1-5) appears

next, which shows the current database information
on the NavData and Terrain Data Cards. Database
information highlighted in yellow indicates the database
is not within its effective dates. The NavData database is
updated every 28 days and must be current for approved
instrument approach operations. Information on database
subscriptions is available inside the GNS 530 package.

Figure 1-5 Database Versions Page

Acknowledging the database information:

Press the ENT Key.

Figure 1-6 Instrument Panel Self-Test Page

Check CDI/HSI, RMI, and

Other Instruments to verify

these Indications

Fuel Capacity is

entered manually

Fuel On-Board

and Fuel Flow

are Provided

by Sensors, if

Installed
Select to Set

Fuel Level to

Full Capacity

Select to display

Checklists Page

Should Match Current

OBS Course Selection

Instrument Panel Self-test Page

Once the database has been acknowledged, the

Instrument Panel Self-test Page appears (Figure 1-6).

To ensure that the GNS 530 and any connected

instruments are working properly, check for the following
indications on the CDI/HSI, RMI, external annunciators,
and other connected instruments:

• Course deviation - Half left/no flag
• TO/FROM flag - TO
• Bearing to destination - 135°
• Distance to destination - 10.0 nm
• All external annunciators (if installed) - On
• Glideslope - Half up/no flag
• Time to destination - 4 minutes
• Desired track - 149.5°
• Ground speed - 150 knots

The Instrument Panel Self-test Page indicates the

currently selected OBS course, fuel capacity (CAP), fuel
on board (FOB), and fuel flow (FF). The fuel capacity,
fuel on board, and fuel flow may be manually entered if
the installation does not include connection to sensors
which automatically provide these figures.

Entering fuel capacity, fuel on board,
or fuel flow figures (if not provided by
sensors):

1) Turn the large right knob to select the Fuel

Capacity, Fuel on Board, or Fuel Flow field.

2) Turn the small and large right knobs to enter

the desired figure (Figure 1-7) and press the
ENT Key.