Trouble shooting guide – RIDGID SeekTech ST-305 User Manual

Page 12

Advertising
background image

Ridge Tool Company



Tools For The Professional

TM

SeekTech

®

ST-305

Trouble Shooting Guide

PROBLEM

REMEDY

LEDs appear completely

dark, or completely light

when unit is ON.

Try Powering the unit OFF and then back ON.
Allow the unit to cool if it has been exposed to excessive heat from sunlight.

Receiver will not pick

up the line transmitter’s

signal.

Check that the correct frequency has been selected on both units.

(See manual for the specific receiver.) Higher or lower frequencies may be tried.
Check to make sure that the receiver and the line transmitter are in the same mode.
Make sure that the proper functions are activated on the receiver. e.g. activating the line trace

function for line tracing.(See manual for the receiver.)
Adjust power upward if possible.
Ensure grounding is adequate.

Unit will not turn ON.

Check orientation of batteries.
Check that the batteries are fresh or charged.
Check to see that the battery contacts are OK.

93 kHz signal not

received

Check that receiver is set to the actual 93 kHz freguency of 93,696 Hz. Some receivers use a

different frequency for 93 kHz (93,622.9). Update SeekTech locator software.

Advertising