V1225, V1250

Ridge Tool Company

2

• Due to the high suction force and fl ow-promoting container shape,

some water may fl ow out of the hose when the appliance is switched

off.

• Use a dry fi lter for subsequent dry vacuum cleaning. Use a second

(exchange able) fi lter when frequently alternating between dry and wet

vacuum cleaning.

Filter cleaning

The vibrating device should be activated (switch position AR) at the latest

when the volume fl ow display 2c (warning light) lights up or when the

suction power decreases

Emptying the container

Turn off (2a), disconnect the plug (6), and open the lock-in closure (9).

Remove the top section (1) and hose from the container (7). Empty the

container or remove the paper fi lter bag from the suction opening.

Paper fi lter bag (Accessory)

Hold of the paper fi lter bag by the fl ange and push vertically from above into

the guide of the suction opening (8) until the stop point is reached. Bags

increase the dust-retaining capacity and ensure hygienic disposal. Paper

fi lter bags must only be used for dry vacuum cleaning.

Cleaning

Dry the fi lter and container thoroughly so that dust cannot adhere to moist

parts. To prevent dirt accumulation and encrustation, dry dust must be

removed before changing over to wet vacuum cleaning. Clean the container

and accessories with water. Wipe the top section (1) with a moist cloth.

Maintenance

The fi lter cassettes (12) must be renewed when the suction power declines

and does not increase again after the fi lter w has been cleaned. Obviously,

this presupposes that the container (7) has been emptied and a full paper

fi lter bag (12) has been replaced. Shake the fi lter cassettes once again

before the fi lter is exchanged. Use a coin or similar object to turn the lock

(5) on the locking bar (4) anti-clockwise by 90°, and then push the locking

bar (4) to the back. Fold open the hood and lift out the fi lter cartridges (12).

Insert new fi lter cassettes. Ensure that the fi lters are correctly and securely

seated. The motor protection fi lter (13) must be cleaned from time to time.

Remove the fi lter from the motor case. Wash the fi lter under fl owing water

and then dry thoroughly. Return the motor protection fi lter. Remove any dirt.

Fold down the hood and press it lightly so that the locking bar (4) returns to

its initial position. The appliance is now properly closed.

Remedying faults

Functional faults are not necessarily always due to a defective appliance.

Fault: Possible

Cause/Remedy:

Decreasing suction force.

Clogged fi lter – Clean

Paper fi lter is full – Change

Container full – Empty

Clogges motor protection fi lter – Clean

Clogged nozzle, tube or hose – Clean

Appliance does not start.

Is the plug inserted in the socket?

Mains failure?

Is the power supply cable broken?

Has the appliance hood been properly

closed?

Has the water sensor switched off the

appliance?

No other interventions are permitted; please consult the servicing
workshop.