3 0

• REGULATING THE MINIMUM FLAME

If you have changed the type of gas, it is important to verify the flame stability at the
minimum regulation.

"Gaining access to the by-pass screw"

To gain access to hob burner by-pass screws, remove the knobs from the control panel.

By-pass screw of the hob burner

Never loosen
the others screws !

REGULATING THE MINIMUM FLAME ON THE HOB BURNER

a) Natural gas :

. simply loosen the screw.
. switch on the burner and turn the knob to minimum.
. Turn the by-pass screw until a low flame is visible. Turn the control knob from
minimum to maximum position to check that it is satisfactory.

b) Butane-propane gas :

The by-pass screw should be screwed fully home, without being locked.

!

INSTALLATION:

"REGULATING THE FLAME"

Advertising