CONNECTION TO THE TERMINALS ON THE TERMINAL BLOCK :
To proceed with the connection, you must adhere to the following instructions.
. Before making the connection, make sure that the installation is protected by a suitable
fuse, see table on next page, and that it is fitted with wires of a large enough section to
supply the appliance normally.
. Choose the supply cord in accordance with the recommendations in the table next
page.

. Turn the hob, with the glass side against the worktop, providing you have protected
the glass !
. Remove the cover located under the control knobs, fitted by 2 screws at the front.

. Pass the supply cord into the cover hole.
. Pass the supply cord into the clamp.
. Strip the end of each conductor of the supply cord on a 10 mm length, by taking
account of the requested length of the cord for the connection on the terminal block.

. The terminal block offers different types of connection.
So, in accordance with installation instructions and
with the help of shunt bars*, fix the conductors as
shown on the chart in next page.
* The shunt bars, placed on the Earth Terminal,
allow to make a bridge between two phases.

. Screw the cable clamp back.

. Screw the cover hole back.

INSTALLATION - ELECTRICAL CONNECTION

Shunts bars

Earth
Terminal

Cord clamp

Terminal block

with marks

1 2 3 4 5

Note :

Please take care to ensure that the shunt
bars do not fall through the hole.