3 transport and interim storage, 4 intended use, 5 details about the product – Wilo Drain TM 25_6 User Manual

Page 10: 1 type key, Technical data, 3 scope of delivery, 4 accessories

Advertising
background image

English

Installation and operating instructions Wilo-Drain TM 25/6

9

3 Transport and interim storage

On receipt of the product immediately check for
transport damage. If damage has occurred, take
the necessary steps, within the defined periods,
with the transport company.
CAUTION! Danger of material damage!
There is a danger of damage if the product is
incorrectly handled during transport or storage.

• For transport, the pump may only be lifted or

carried using the brackets intended for that pur-
pose. The cable should never be used for lifting!

• During transport and temporary storage, the

pump must be protected from moisture, from
frost and from mechanical damage.

4 Intended use

The Wilo-Drain-TM submersible pumps are used

• to automatically drain pits and shafts („TM...A“),
• to keep out buildings and cellars at risk of flooding

dry,

• to lower surface water,

so far that waste water can't flow into the sewage
system via a natural gradient.
The pumps are suitable for slightly soiled water,
rainwater containing solids of max.

∅ 3 mm and

suds.
The pumps are usually installed flooded
(immersed) and can only be installed vertically,
whether fixed or mobile.
Submersible motor pumps with connection lines
of less than 10 m are only approved (according to

EN 60335) for use within buildings, not for out-
door use.
WARNING! Risk of fatal injury!
The pump may not be used to empty swimming
pools / garden ponds or similar locations if there
are people in the water.
WARNING! Health risk!
Owing to the materials used, the pumps are not
suitable for drinking water! Polluted waste
water presents a health risk.
CAUTION! Danger of material damage!
Pumping materials which are not approved can
lead to damage to the product.
The pumps are not suitable for water containing
coarse impurities such as sand, fibres or faeces,
flammable liquids or for use in areas at risk of
explosion.

5 Details about the product

5.1 Type key

5.2

Technical data

5.3 Scope of delivery

Every pump is delivered with

• 5/10 m connection cable,
• a mains power plug,
• connected float switch („TM...-A“),
• hose connection (in steps Ø 20, 25 mm, R1“),

• coupling (Rp 1 / Rp 1¼) with integrated non-

return valve,

• installation and operating instructions.

5.4 Accessories

Accessories must be ordered separately (see cat-
alogue)

Examples:

TM 25/6 A 5MKA, TM 25/6 5MKA

TM 25/6 A 10MKA, TM 25/6 10MKA

TM

series: submersible pump

25

nominal diameter of the pressure port [mm]

/6

max. head of water [m] for Q=0m³/h

A

A = with float switch
- = not specified:

no float switch

10M KA

length of connection cable [m]: 5, 10

max. permissible grain size:

3 mm

supply voltage:

1~ 230 V, ± 10 %,

supply frequency:

50 Hz

protection class:

IP 68

speed:

max. 2900 ¹/min (50 Hz)

max. current consumption:

0,8 A

power consumption P

1

:

0,18 kW

nominal motor power P

2

:

0,1 kW

max. flow rate:

see name plate

max. head of water:

see name plate

operating mode S1:

200 hours of operation per year

operating mode S3 (optimum):

intermittent duty, 25 % (2.5 min. operation, 7.5 min. pause)

recommended switching frequency:

20 times/h

max. starts per hour:

50 times/h

nominal diameter of the pressure port:

25 mm

permissible temperature range of the
pumped liquid:

+3 to 35°C

max. immersion depth:

5 m

level suction to

5 mm

noise level at min. level

< 57 db(A)