ACR&Artex Float-Free 406 Memory Capsule User Manual

Page 16

Advertising
background image

12

Y1-03-0202 Rev. E

Bytes 0 – 6, 10, and 11 are part of the command string sent by the
user to the RLB-35MC Memory Board. Bytes 7 – 9 and 12 – 14 are

returned by the RLB-35MC Memory Board with the echoed command
string in response to a ‘Test’ command (‘E’ command and ‘0’

subcommand); only bytes 12 and 13 are returned with the command
string in response to a ‘Status’ command (‘S’ command).

6.2. Header

The first four (4) bytes are a fixed value header with hexadecimal
values of AC, 53, CA, 35.

6.3. Operation Command

Byte 4 is the Operation Command and is in ACSII format:

ASCII

Character

Hex

Value

Command

R

0x52

If main memory, read the read offset specified number MB of data, else
read & return all the data from the specified memory partition.

W

0x57

Write into the specified memory partition

D

0x44

Read all of main memory starting at the specified read offset from the
current write address and ending at the address just before the stating
address

P

0x50

Read main memory from the partition’s beginning address to the current
write address

F

0x46

Read all of main memory starting at the partition’s beginning address to
the ending address

S

0x53

Request the memory board status

E

0x45

Request the memory board status, CFC size, & software version


6.4. Operation Subcommand

Byte 5 is the Operation Subcommand, and is in ASCII format. It
defines which partition of memory each read or write command will

operate on.

ASCII

Character

Hex

Value

Definition

0

0x30

Test status request

1

0x31

Main memory partition

2

0x32

Configuration memory partition

3

0x33

Status memory partition