Tcp/ip communications data write example, Start – ACR&Artex Float-Free 406 Memory Capsule User Manual

Page 21

Advertising
background image

17

Y1-03-0202 Rev. E

9. TCP/IP Communications Data Write Example



Send write command

to RLB-35MC

Start

Command echoed

back?

Send data packet to

RLB-35MC

End of data?

Close socket

connection

End

Yes

No

No

Yes

Open socket

Connection on Port

7000

Write data into main data partition.
AC,53,CA,35,57,31,00,00,00,00,00,00,00,00,00,00

All write commands are on port 7000.


See section 5.3 for how to execute this sequence using our demo software.