Appendix B - Board Configuration Differences

42

Appendix B

Noted Board Configuration Differences

Because of Schlage Biometrics’ camera retrofit of the HandPunch some changes have
been made to the main PCB and they are listed as follows:

• Dipswitches have been removed

- memory is reset with a push-button reset and user interface with keypad and LCD

• Power has moved to the right side of the PCB
• The RS-232 RJ-45 receptacle has been replaced with a 4 pin Molex connector on the

left side of the PCB

• A 2 pin Molex connector (J5) has been added to the board, next to the reset button,

to supply power for the LEDs. This connector should never be unplugged. unless a
modem or Ethernet is added to the PCB

• The upgrading of the memory is now handled through software codes at the

HandPunch. Contact Order Entry for memory upgrades

To reset the memory of the HandPunch follow these steps-

1. Remove power and battery jumper, if a back up battery is installed
2. Press down on reset button and apply power
3. Release button
4. Reader will boot to

ERASE

:1 SETUP

:9 ALL!!!

• Press 1 to erase setup i.e. address, outputs, passwords, but retain user database and

datalogs

• Press 9 to erase everything i.e. HandPunch goes back to factory defaults