12) Optional Retest - 1987 & Newer

• Lightly press and release throttle

within 2 minutes after the last code
is sent. This will repeat the entire
cylinder balance test.

• IMPORTANT: (Some 1987 and all

1988 & newer) Repeating the test

can tell you how weak a bad
cylinder is. (The computer alters
inspection during retest.) Test
results will be different for a good,
weak or “dead” cylinder. See charts
below using cylinder #7 as an
example.

Example: All cylinders equal

1st TEST

2nd TEST

3rd TEST

Code #9 (pass)

Not necessary

Not necessary

Example: Cylinder 7 is weak

1st TEST

2nd TEST

3rd TEST

Code #7

Code #9 (pass)

Not necessary

Example: Cylinder 7 is very weak

1st TEST

2nd TEST

3rd TEST

Code #7

Code #7

Code #9 (pass)

Example: Cylinder 7 is extremely weak or dead

1st TEST

2nd TEST

3rd TEST

Code #7

Code #7

Code #7

Service Code

Test Results

9

System PASS

1

#1 Cylinder / Injector problem

2

#2 Cylinder / Injector problem

3

#3 Cylinder / Injector problem

4

#4 Cylinder / Injector problem

5

#5 Cylinder / Injector problem

6

#6 Cylinder / Injector problem

7

#7 Cylinder / Injector problem

8

#8 Cylinder / Injector problem

77

Throttle was moved during test. Testing could not be
completed. Repeat test procedure starting from step 1.

13) Turn Ignition Key to Off Position

14) Disconnect Code Scanner

Advertising