Code Scanner Power

A 9 volt transistor radio battery (NEDA
1604) is required to power the Code
Scanner. Either a regular or alkaline
battery may be used. The Code
Scanner has an automatic battery shut-
off when not in use. There is no “power
off” switch because the unit uses no
power when the light is off and the tone
is quiet. The battery must be installed
before use.

Installing the Battery

Do the following:

1) Remove two screws from the bottom

side of the Code Scanner.

2) Separate the two halves of the Code

Scanner.

3) Insert battery:

4) Reassemble Code Scanner case

and replace screws.

Checking the Battery

Do the following:

1) Put the Hold/Test switch in TEST

position.

OFF

AUDIO

ON

CP9015 – Ford, Lincoln & Mercury

Domestic 1981& Newer

TM

®

TEST

ST0

HOLD

S

EL

F

TES

T OU

TP

U

T

2) Put the Audio switch in ON position.

3) Use a coin to touch the two side-by-

side terminals on the bottom row (the
one with three terminals) of the Code
Scanner connector.

4) Both the STO light and the tone

should turn ON. Replace battery
when the light or tone gets weak.