13 evs controller settings, 1 effect duration for take, 2 fast jog – EVS XSense Version 10.04 - January 2011 Configuration Manual User Manual

Page 73: 3 pgm speed/var max, 4 lever engage mode

Advertising
background image

Issue
10.04.B

XSense – Version 10.04 – Configuration Manual

EVS Broadcast Equipment – January 2011

64

3.13 EVS CONTROLLER SETTINGS

EVS Controller p.6.1
[F1]Effect duration for Take: 00s05fr
[F2]Fast jog : 20x
[F3]PGM Speed/Var Max : 50%
[F4]Lever engage mode : Direct
[F5]Second lever range : -100% <-> +100%
[F6]Recall Clip Toggle : Enable
[Menu]Quit [Clr+F_]Dft [F9]PgUp [F0]PgDn

3.13.1 E

FFECT

D

URATION FOR

T

AKE

Possible range: 00s00fr to 20s00fr. Default: 00s05fr

This parameter defines the duration of the transition when using the TAKE key to
chain 2 sequences in PGM+PRV mode.

3.13.2 F

AST

J

OG

Possible values: 01 to 20 times. Default: 20x

This parameter sets the increment of the jump when in Fast Jog mode.

3.13.3 P

GM

S

PEED

/V

AR

M

AX

Possible values: 1 – 400%. Default: 50%

During playback, if PGM Spd or VarMax has been enabled in the secondary menu

of the Remote Panel, the lever range will be adapted so that:

•

the only playback value for any position of the lever other than 0, is the one

specified by this parameter in the setup (PGM Spd mode ON)

OR

•

the speed range defined by the lever is limited to the value specified by this

parameter (VarMax mode ON).

3.13.4 L

EVER

E

NGAGE

M

ODE

Possible values: Direct (default) / Current speed

The speed variation depends on the position of the T-Bar lever.

•

Direct mode: the lever will engage directly when moved, resulting in a speed

jump to the desired speed determined by the lever arm position.

•

Current speed mode: the lever will only engage when it reaches the current

playback speed, whereas a move of the lever arm in the opposite direction of
the current speed will result in a direct speed change.