INSTALLATION INSTRUCTIONS

5

M S D  

•   W W W . M S D P E R F O R M A N C E . C O M   •   ( 9 1 5 )   8 5 7 - 5 2 0 0   •   F A X   ( 9 1 5 )   8 5 7 - 3 3 4 4

PROGRAMMING

CYLINDER SELECT

The MSD is programmed for operation on 8-cylinder engines.

If installing the Ignition on a different style engine, the number

of cylinders will need to be selected by cutting the cylinder

select wire loops as shown in Figure 1.

REV LIMITER

Routing Wires: The MSD wires should be routed away from direct heat sources such as exhaust

manifolds and headers and any sharp edges. The trigger wires should be routed separate from the

other wires and spark plug wires. It is best if they are routed along a ground plane such as the block

or firewall which creates an electrical shield. The magnetic pickup wires should always be routed

separately and should be twisted together to help reduce extraneous interference.

DIGITAL 6AL

REV

LIMITER

Figure 2 Adjusting the Rev Limits.

The rev limiter can be set from 2,000 to 11,000 rpm. To adjust

the rev limiter of the Digital 6AL, remove the black cover next

to the LED by prying up with the supplied screwdriver. The

dial on the left is for 1,000 rpm increments, on the right is for

100 rpm increments.

For a rev limiter in the 10,000 range, set the dials as they

would be for any other RPM but the left dial will use '0'. To

set the rev limiter to 11,000 rpm, put the left dial to '1' and

the right dial to '0'. Setting both rotary dials to '1' will activate

a special function explained below.

Note: The engine can be running as you make adjustments

to the rev limiter function.

REV LIMITER VERIFICATION

The MSD Digital 6AL has an optional built in Rev Limiter

Verification feature. When the key is in the On position

(not cranking or running), an rpm signal is sent to the

tachometer to verify the unit's rev limit setting. With this

function users can be sure of their rev limit settings before

each drive.This feature is not activated from the factory. To

enable this feature, follow the procedure below.

Note: It is important to note that this feature should not

be used with EFI systems. When activated, an rpm signal is sent to the tachometer. With an

aftermarket EFI system, this could activate the injectors causing a flooding situation.

Enable Rev Limit Verification

1. With the ignition switch in the off position, ground the Gray tach output wire.

2. With the Gray wire connected to ground, turn on power to the ignition without starting the engine.

3. Hold the Gray tach output wire to ground for seven seconds. (AT LEAST five seconds.)

4. Release the wire from ground before ten seconds have passed.

5. To confirm the process has worked, cycle turn the key On. The tachometer should sweep to the

rpm limit set on the ignition.

As soon as this process is complete the feature will be activated. The Digital 6AL uses the red LED to

help indicate when an adequate amount of time has passed to release the Gray tach wire. The LED

will turn on after the wire has been grounded for five seconds and will turn off at the 10 second mark.

To deactivate the feature again, repeat the same process.

CYLINDERS

WIRE LOOPS

8

No Cut Loops

6

Cut One Loop

4

Cut Both Loops

1,000's

100's

Figure 1 Programming the Number of

Cylinders.