Installation info – MSD 5099 DynaForce Starter, AMC (All except 4.0L) Installation User Manual

Page 3

Advertising
background image

INSTALLATION INSTRUCTIONS

3

M S D  

•   W W W . M S D P E R F O R M A N C E . C O M   •   ( 9 1 5 )   8 5 7 - 5 2 0 0   •   F A X   ( 9 1 5 )   8 5 7 - 3 3 4 4

INSTALLATION INFO

INSPECT PINION GEAR

After cranking the engine several times, you can inspect

the witness pattern on the pinion gear. The pattern should

show 1/4" to 3/8". If over, the internal shim is required.

SLOW CRANKING

The most common cause is due to low input voltage. The

battery should be checked, but also inspect the battery

wires, terminals, connections or switches.

DISCONNECT SWITCHES

Most sanctioning bodies require an emergency disconnect

switch. Be sure to use a heavy duty switch that is capable

of handling high current. Some starters may pull over 700

amps while cranking. Most disconnect switches are rated

at continuous and intermittent amps. Make sure to use a

switch that exceeds your starting and electrical system

requirements.

R-TERMINAL

On older vehicles, mostly with breaker points, there was

an extra terminal and wire on the original starter (the MSD

DynaForce Starter does not have this terminal). This

extra terminal served as a ballast resistor bypass. When

the starter was cranking, 12 volts would be supplied on this terminal and directly to the coil positive

terminal for starting assistance.

Most ignition systems today do not need this terminal, however, if your ignition has no voltage when

cranking you can wire a system. Connect a 10A/250V diode in-line with the motor side of the solenoid.

The banded end of the diode goes away from the starter. This allows current to go to the ignition coil

during cranking and will not feed back to the starter while the engine is running.

Figure 6 Pinion Gear Pattern.

THE CORRECT PINION DEPTH

SHOULD MEASURE 1/4” to 3/8”.