10

INSTALLATION INSTRUCTIONS

M S D

•   W W W . A T O M I C E F I . C O M   •   ( 9 1 5 )   8 5 5 - 7 1 2 3   •   F A X   ( 9 1 5 )   8 5 7 - 3 3 4 4

®

LS

FUEL PUMP

GROUND

BATTERY 1*

BATTERY 2*

CAN

ONLY

HANDHELD

MONITOR

SLED POWER

FAN 1

LAUNCH

NITROUS

SPEED REF

SPEED

TACH

SW 12V

FAN 2

MIL GROUND

IP

VM

H-

H+

IA

UN

RED

YELLOW

BLK/WHT

BLK/RED

GREEN

BLACK

TO PASSENGER

FUEL RAIL

TO PASSENGER

FUEL RAIL

POWER TO

PASSENGER

FUEL RAIL

CONTROLLER

MONITOR

CONNECTOR

ONLY

* BATTERY 1 AND 2

MUST BOTH BE

CONNECTED

Figure 15 Power Module Wiring Diagram.

POWER MODULE INSTALLATION

The Power Module of the Atomic EFI system handles

high current circuits such as the fuel pump and WBO2.

The unit has two ports for the MSD CAN system as

well as a wiring harness. The CAN ports will provide

communication between the Power Module, the

passenger side fuel/ECU rail and the Handheld Monitor.

It is important to select a proper mounting location for the

Power Module. The unit can be mounted in the interior

or the engine compartment as long as it is away from

direct heat sources. It is not recommended to mount the

unit in an enclosed area, such as the glovebox. When

a suitable location is found, make sure all wires reach

their connections. Also be sure that the CAN port can

be accessed for use with the Handheld Monitor.

Use the Power Module as a template and mark the location of the holes. Use a size #20 drill bit to

prepare for the supplied self tapping screws. Install the supplied rubber grommets (Figure 14).

POWER MODULE

WIRING

There are a number of

electrical connections on

the Power Module that

are required for proper

operation (Figure 15). Other

wires, such as the nitrous

input, 2-step rev control or

electric fan controls, only

need to be connected if

their optional functions are

being used. In the chart

below, wires marked “REQ”

must be connected for the

system to operate while

those marked “OPT” are

optional depending on

the features being used.

For the installation it is

recommended to connect

only the required wires.

Figure 14 Power Module Wiring Diagram.

®