MSD 7531 Programmable Digital-7 Plus Installation User Manual
Page 12

12
INSTALLATION INSTRUCTIONS
M S D
• W W W . M S D P E R F O R M A N C E . C O M • ( 9 1 5 ) 8 5 7 - 5 2 0 0 • F A X ( 9 1 5 ) 8 5 7 - 3 3 4 4
ALERTS
This is used with the Hand Held Monitor, PN 7550 and a pop up alert window appears on the PC
screen. You can program an alert to interrupt the screen on the monitor. You can select which alerts
to show and how often. The alerts are No Cam Sync and Low Battery.
Fault: Program the number of counts that occur for a Low Voltage reset or WatchDog reset.
BrownOut 0: This is the count of low voltage resets. This should always be set at 0.
WatchDog: The count of WatchDog resets. This should always be set at 0.
ACQUIRE
Arm LaunRevLim: This is where you program how to activate the Launch History recording to begin.
Choose between Off, Launch Rev Limit or Launch. Default is the Launch Rev Limit.
Off: Deactivates the Run History.
Launch: The Run History acquisition begins recording when the car launches (Dark Blue wire
is removed from 12 volts).
LaunRevLimit: The Run History acquisition begins when the launch rev limit is activated (Dark
Blue wire is activated).
Note: The Light Blue burnout wire, when at 12 volts, will reset the History Record.