EN-2 RS485 / RS422 Option Kit

2.2 RS485 / RS422 Wiring Guidelines


• Do not run more than one cable through the strain relief bushing.
• Do not use the cable that connects to the RS485 / RS422 pc board to make other

connections.

• Twisted pair shielded cable is recommended.
• The strain relief bushing

allows a cable diameter from 2 to 6 mm (0.08 to 0.23

in.).

• The terminal block on the RS485 / RS422 pc board allows a wire size of 0.14 to

1.5 mm

2

(26 to 16 AWG). Strip the wire ends to 6 mm (0.25 inch).

Figure 2.1 Wire Preparation



• Connect the wires to the terminal block J2 according to the Figure 2.2.

Operating Mode
Jumper location

Receive - (RXD

-

)

Receive + (RXD +)
Ground (GND)
Transmit - (TXD

-

)

Transmit + (TXD +)

Termination Resistance
Jumper location

W1 W2

J1

J4

J2

Figure 2.2 RS485 Connections