Lubrication

Horizontal Mounting

12° Installation

12° Installation with Standpipe

Note: Grades must be continuous or lengthy in nature. Moni-

tor oil temperatures before installing standpipes. Axles
should operate at approximately 100°F (38°C) over am-
bient temperature and not exceed 240°F (116°C).

Final Check

Prior to putting vehicle back into service, run the vehicle to
bring axle lube up to temperature. Check filler and drain plugs
and axle joint for leakage. Re-tighten to specifications as nec-
essary.

1 - Oil filller hole
2 - Lost oil capacity
3 - Additional oil capacity