ENVIRONMENTAL SENSORS

INSTALLATION GUIDE

Environmental CO

2

Sensors

SPECIFICATIONS

Input Voltage

20 to 30VDC, 24VAC

Analog Output #1

4-20mA (clipped & capped) or 0-3VDC/0-5VDC/0-10VDC

(jumper

selectable)

Analog Output #2

4-20mA (clipped & capped) or 0-3VDC/0-5VDC/0-10VDC

(jumper

selectable)

Sensor Current Draw

200mA Maximum

Operating Humidity Range

0-95% RH (noncondensing)

Operating Temperature Range

0° to 50°C (32° to 122°F)

Housing Material

High impact ABS plastic

Relay Contacts (optional)

Form C (SPDT) 1A@30VDC, resistive; 30W max.

CO2 Transmitter:

Sensor Type

Non-dispersive infrared (NDIR), diffusion sampling

Measurement Range

0-2000 ppm

Accuracy

±40 ppm ±8.5% of measured value

Repeatability

±30 ppm ±4.5% of measured value

Response Time

<60 seconds for 90% step change

EMC Conformance: EN 61000-6-3:2007+A1:2011 Class B, EN 61000-6-1:2007

EMC Special Note: Connect this product to a DC distribution network or an AC/DC power adaptor

with proper surge protection (EN 61000-6-1:2007 specification requirements).

RTD/Thermistors are not compensated for internal heating of product.

CWV SerieS

DIMENSIONS

NOTICE

• This product is not intended for life or safety applications.

• Do not install this product in hazardous or classified locations.

• Read and understand the instructions before installing

this product.

• Turn off all power supplying equipment before working on it.

• The installer is responsible for conformance to all applicable codes.

No responsibility is assumed by Veris Industries for any consequences arising out of the

use of this material.

PRODUCT IDENTIFICATION

INSTALLATION

1. Select a mounting location with good air circulation. For room installations, mount

the sensor 4 ½ feet (1.4 m) above the floor.

2. Remove the cover. Flush mount the CWV on a wall or on a standard US or European

single gang junction box.

3. Wire the device. Refer to the wiring diagram.

4. Install the cover.

MOUNTING

4.6"

(116 mm)

3.3"

(84 mm)

1.4"

(36 mm)

.64”

(16 mm)

.46"

(12 mm)

4.6"

(116 mm)

2.2"

(54 mm)

1.6"

(42 mm)

3.3"

(84 mm)

CWVS

Output

Warranty

1 = 0-3/5/10VDC
and 4-20mA
2 = 4-20mA and
4-20mA
3 = 0-3/5/10VDC
and 0-3/5/10VDC

1 = 1 year
3 = 3 years
5 = 5 years

Housing

Relay option

Blank = White/
gray
B = Black

Temp/2nd
Relay option

X = No temp.
1 = Relay
B = 100R Pt
C = 1k Pt
D = 10k T2
E = 2.2k
F = 3k
H = 10k T3
J = 10k Dale
K = 10k with 11kS
M = 20k NTC
N = 1800 ohm
R = 10K US
S = 10K 3A1B

X = No relay
1 = Relay