Veris Industries A8911–23 Datasheet User Manual

Pulse input module, Up to 23 separate pulse inputs, Net w ork inte gra tion

Advertising
background image

net

w

ork inte

gra

tion

VERIS INDUSTRIES

800.354.8556

+1 503.598.4564

www.veris.com

SPECIFICATIONS

Processor

ARM 7, field upgradable firmware

LED

23 input status LEDs (red), 2 Modbus TX/RX (yellow), 1 power/alive status (green)

Protocols

Modbus/ RTU

Power Supply

9VDC to 30VDC, 200mA (not included)

Serial Port

RS-485 2-wire, 19200 or 9600 baud. N81

Pulse Inputs

23 independent pulse count inputs; 32-bit pulse counter; rolls over at 4.295 billion per channel;

Intended for use with dry contact outputs; pulse count values stored in nonvolatile memory; Pulse rate/width user selectable to 10 Hz, 50 Hz, or 100 Hz

Minimum Pulse Width:

10 Hz Mode

50 msec

50 Hz Mode

10 msec

100 Hz Mode

5 msec

Contact Closure Threshold

100 Ω to 5 kΩ (user selectable)

Isolation

Pulse inputs, power inputs and RS-485 are non-isolated

Operating Environment:

North America

Indoor, 0° to 50°C (32° to 122°F), 0-95% RH noncondensing

Agency Approvals

FCC CFR 47 Part 15, Class A

DESCRIPTION

The A8911-23 Input Module provides an easy way to integrate multiple pulse output

devices to Modbus systems such as the Veris AcquiSuite data acquisition network.

The A8911-23 accepts up to 23 standard pulse sensors and can function as a slave

device with any Modbus master. This data can be networked to other critical energy

sensors such as Veris Modbus power meters to provide a comprehensive energy

monitoring solution.

APPLICATIONS

●

Demand response program control and reporting

●

Cost allocation to tenants and third parties

●

Measurement and verification of energy savings

●

Gas, water, steam, and BTU meters

●

Monitoring performance of building systems (e.g., chillers, boilers, fans)

FEATURES

●

External communications via shielded twisted pair 18-22 gauge wire...allows
communication up to 4000 feet

●

Pulse input communication up to 200 feet using 18-24 gauge control wire

●

DIN rail mounting...quick and easy installation

●

Onboard DIP switches for Modbus addressing

●

Industry standard pulse inputs connect to most pulse output meters

●

LED verification of RS-485 Modbus TX/RX communications

●

LED indicators for each pulse input...fast indication and verification of pulses

●

Non-volatile memory retains configuration and pulse count totals during

power failures

Up to 23 Separate Pulse Inputs

Pulse Input Module

A8911-23 is sold as an open device.

Observe handling precautions for static sensitive

devices to avoid damage to the circuitry which

would not be covered under the factory warranty.

A8911-23

A8911–23

Year

Warranty

2

HQ0001806.B 01131