Po wer/ener g y monit oring, Dimensional drawing ordering information, Mounting diagrams – Veris Industries E5xxxA SERIES Datasheet User Manual

Page 2: Accessories, Required cts, Din mount configuration screw mount configuration, U018 series

Advertising
background image

p

o

wer/ener

g

y monit

oring

800.354.8556

+1 503.598.4564

www.veris.com

4.2”

(107mm)

3.6”

(91mm)

1.5”

(39mm)

2.3”

(59mm)

1.9”

(48mm)

1.8”

(45mm)

DIMENSIONAL DRAWING

ORDERING INFORMATION

3.6 “

(91 mm)

4.2 “

(107 mm)

0.2 “

(4 mm)

3.9“

(99 mm)

2.4 “

(61 mm)

+

+

+

4.3 “

(109 mm)

1.2 “

(31 mm)

0.3 “

(8 mm)

0.4 “

(10 mm)

MOUNTING DIAGRAMS

DIN Mount Configuration

Screw Mount Configuration

ACCESSORIES

NEMA 4X enclosure (AE012)
Fuse Kits with hi-interrupt capability AC Fuses (AH02, AH03, AH04)
DIN Rail (AV01), DIN Rail Stop Clips (AV02)
Modbus TCP Gateway (U013-0012)
BACnet IP Router (U013-0013)

E51CxA only

E50B1A

E50C2A

E50C3A

E50F2A

E50F5A

E50H2A

E50H5A

E51C2A

E51C3A

E51H2A

E51H5A

MEASUREMENT CAPABILITY - FULL DATA SET

Bi-directional Energy Measurements

n

n

n

n

Power (3-phase total and per phase): Real (kW)

Reactive (kVAR), and Apparent (kVA)

n

n

n

n

n

n

n

n

n

n

n

Power Factor: 3-phase average and per phase

n

n

n

n

n

n

n

n

n

n

n

Present Power Demand: Real (kW),

Reactive (kVAR), and Apparent (kVA)

n

n

n

n

n

n

n

n

n

n

n

Import and Export totals of Present Power Demand:

Real (kW), Reactive (kVAR), and Apparent (kVA)

n

n

n

n

Peak Power Demand: Real (kW),

Reactive (kVAR), and Apparent (kVA)

n

n

n

n

n

n

n

n

n

n

n

Current (3-phase average and per phase)

n

n

n

n

n

n

n

n

n

n

n

Voltage: Line-Line and Line-Neutral

(3-phase average and per phase)

n

n

n

n

n

n

n

n

n

n

n

Frequency

n

n

n

n

n

n

n

n

n

n

n

ANSI C12.20 0.5% accuracy, IEC 62053-22 Class 0.5S

n

n

n

n

n

n

n

ANSI C12.20 0.2% accuracy, IEC 62053-22 Class 0.2S

n

n

n

n

Accumulated Net Energy: Real (kWh),

Reactive (kVARh), and Apparent (kVAh)

n

n

n

n

n

n

n

n

n

n

n

Accumulated Real Energy by phase (kWh)

n

n

n

n

n

n

n

n

n

n

n

Import and Export Accumulators of

Real and Apparent Energy

n

n

n

n

Reactive Energy Accumulators by Quadrant

(3-phase total and per phase)

n

n

n

n

Demand Interval Configuration:

Fixed or Rolling Block

n

n

n

n

n

n

n

n

n

n

n

Demand Interval Configuration:

External Sync to Comms

n

n

n

n

n

n

n

n

n

n

DATA LOGGING:

Data Logging: 10 16-Bit Configurable

(can include Date/Time) Data Buffers

n

n

Data Logging: 3 Timestamped 32-Bit

Configurable Data Buffers

n

n

n

Store up to 60 days of readings

at 15-minute intervals

n

n

n

n

n

OUTPUTS:

Alarm Output (N.C.)

n

n

n

n

n

n

n

n

1 Pulse Output (N.O.)

n

n

n

n

2 Pulse Outputs (N.O.)

n

RS-485 Serial (Modbus RTU Protocol)

n

n

n

n

RS-485 Serial (BACnet MS/TP Protocol)

n

n

n

n

LON FT Serial (LonTalk Protocol)

n

n

INPUTS:

2 Pulse Contact Accumulator Inputs

n

n

n

1 Pulse Contact Accumulator Input

n

n

n

AH04

AE012

AV01/AV02
(clip styles may vary)

U013-0012

U013-0013

E50FxA only

HQ0004397.B 09131

RoHS

Compliant

coming

soon

coming

soon

coming

soon

REQUIRED CTs

MODEL

DESCRIPTION

U018-0001

CT, Rope, 12 in, 5000A

U018-0002

CT, Rope, 18 in, 5000A

U018-0003

CT, Rope, 24 in, 5000A

U018-0004

CT, Rope, 36 in, 5000A

U018 Series

Advertising