Installation Guide

Power Monitoring

E51H2, E51H5

TM

R/W

R=read only; R/W=read or write

NV

Value is stored in non-volatile memory. The value are still available if the meter experiences a power loss and reset.

Units

Lists the physical units that a register holds.

Legend

Device Object

Property

R/W

NV

Value Returned

Additional information

Object_Identifier

R/W

NV

Device<n>

n is the 7 digit ID # set in the ID1 & ID2 setup screens on the meter. The BACnet Device

ID is a decimal number from 1 to 4,193,999 that can be entered or viewed on the user

screens or through this property. The default value set at the factory is a psuedo-

random number from 1,000,000 to 3,097,151 to reduce the likelihood of conflicts if

multiple units are installed using their default IDs.

Object_Type

R

NV

Device (8)

Object_Name

R

NV

Veris E51 Series Energy Meter - S/N: <serial

number>

Vendor_Name

R

NV

Veris Industries, LLC

Vendor_Identifier

R

NV

133

Model_Name

R

NV

E51Hx Energy Meter

Firmware_Revision

R

NV

<Current Revision #>

“xyyy”.
This is the BACnet processor firmware version in the format <xyyy>, with an implied

decimal point between the first two digits (x.yyy)

Application_Software_ Version

R

NV

<Current version #>

“RS= xyyy, OS=xyyy, BACnet Gateway=xyyy”
The format <xyyy> has an implied decimal point between the first two digits (x.yyy)

Location

R/W

NV

<Location>

Limted to 64 Characters - Default value is “Installed location not yet identified”

Description

R

NV

Veris E51Hx DIN-Rail Energy Meter S/N:

<serial number>

Protocol_Version

R

NV

1

BACnet Protocol Version 1

Protocol_Revsion

R

NV

4

BACnet Protocol Revision 4

Local_Date

R

Date

Set via BACnet Time Synchronization only - reverts to Jan 1, 2000 if control power drops

Local_Time

R

Time

Set via BACnet Time Synchronization only - reverts to 12:00:00 AM if control power

drops

Segmentation_Supported

R

NV

NO_SEGMENTATION (3)

Segmentation is not supported

Max_Master

R/W

NV

1-127 (Factory Default is 127)

Highest possible MAC Address for Master nodes on the local MS/TP network

Max_Info_Frames

R

NV

1

Maximum number of information frames allowed before passing the MS/TP token

Max_APDU_Length_Accepted

R

NV

480

APDU_Timeout

R

NV

60000

Number_of_APDU_Retries

R

NV

0

System_Status

R

NV

Operational (0)

Protocol_Sevices_Supported

R

NV

0b0000000000001011010000000000000

011110000

Protocol_Object_Types_Supported

R

NV

0b1011000010000000000010000000000