Veris Industries H932 Datasheet User Manual

Current sensors with relay: 0-5vdc analog output, Load trending and control relay in one package, Current monit oring

Advertising
background image

current monit

oring

VERIS INDUSTRIES

800.354.8556

+1 503.598.4564

www.veris.com

DESCRIPTION

The Hawkeye 932 and H952 Series provide accurate load trending information

with a proportional 0-5VDC output signal. This feature combined with an integrated

command relay makes these products ideal for start/stop and status monitoring

of motors.

The relay is fully isolated from the current sensor, and all relay connections are

externally available for maximum flexibility.

APPLICATIONS

●

Load trending

●

Motor control

●

Fan/Pump status

FEATURES

●

Self-powered analog current sensor with integral start/stop command relay

●

Reduces the number of installed components... saves time and space

●

Self-gripping split-core for fast retrofit installation...no need to remove

conductor

●

One device to install for start/stop and status...reduces installation charges

●

No external power required for current sensor

●

Selectable factory calibrated ranges up to 120A for increased flexibility

and resolution

●

Factory calibrated switch-selectable ranges (30/60/120A) for high resolution

and installation ease

●

No jumpers on unit...reduces installation error

●

Removable mounting bracket for installation flexibility

●

Bracket can be installed in three different configurations...added flexibility

●

Command relay switches up to 5A@250VAC

●

5-year warranty

SENSED AMPS

30/60/120A*

0V

0A

5V

SENSOR OUTPUT

*Factory calibrated ranges selected

with the amperage range switch

Load Trending And Control

Relay In One Package

H932/952 LINEAR OUTPUT

Scale software as shown

Maximize Reliability

Minimize Installed Cost

SPECIFICATIONS

Sensor Power

Induced from monitored conductor

Insulation Class

600VAC RMS

Frequency Range

50/60 Hz nominal

Temperature Range

-15° to 60°C (5° to 140°F)

Humidity Range

10-90% RH non-condensing

Accuracy

±2% F.S. from 10% to 100% (selected range)

Response Time

2 sec.

Terminal Block Wire Size

24-14 AWG (0.2 to 2.1 mm

2

)

Terminal Block Torque

3.5 to 4.4 in-lbs (0.4 to 0.5 N-m)

Agency Approvals

UL 508 open device listing; CE: EN61010-1:2001-2, CAT III, pollution degree 2, basic insulation

Current Sensors with Relay:

0-5VDC Analog Output

Year

Warranty

5

H932

H932 & H952

TM

HQ0001767.B 01131