Configuration strings, Response strings – Vutec SIK232 Interface - Instructions User Manual

Page 7

Advertising
background image

7 / 13

3.1.2.

Configuration Strings

Configuration strings for the R2D7 are segmented into 3 parts:

* V

;


As with operating instructions, the first character is the header. This is always the
asterisk (“*”).

Next is the setting for the R2D7. The following is a table of valid commands:

V

Print Version (followed by mode: R = Radio, B = Bus)

R

Radio Mode (put system 7 in Radio mode)

B

Bus Mode (put system 7 in Bus mode)


Finally, the terminator is either a semi-colon or the “CR” character.

3.2.

Response Strings

Although the RP-Bus is not bi-directional, the R2D7 does report status information

back to the sender. The following table describes the responses for each event in the
R2D7:

Event

Response

Power On

“version, X-on”

Terminator Received

“LF” if good command
“U” if command was not understood
“CR” after command was relayed to controls

Buffer Overflow

“O”

Buffer In Empty

“XOn” (Ctrl+Q), but only if XOff was sent

Buffer Is Half-Full

“XOff” (Ctrl+s)

Advertising