Velleman DVM831 User Manual

Page 5

Advertising
background image

31.03.2010

Do no

Do no

Do no
circui

When
measu
measu

When
circuit
points

Do n
acces
acces

Switc
batte

All m
Dama
the w

4. Overvolt

DMMs are cate
overvoltage tha
bursts of energ

line.
The existing ca

CAT I

A CAT I
circuits
circuits,

CAT

II

A CAT I
environ
mains b
provide
apart fr
tools…

CAT

III

A CAT I
environ
phased
environ
(fuse bo

CAT

IV

A CAT I
CAT III-
Note th
run outd
used.

Warning:
This device wa
CAT II 500V. T

ot measure circuits th

ot measure current in

ot conduct resistance,

ts.

measuring currents u

urement followed by a
urements.

carrying out measure

ts, always be aware th

s might damage the m

ot replace internal pa

ssories by identical on
ssories e.g. test probe
ch off the meter and re

ry or fuses.
odifications of the dev

age caused by user m

warranty.

tage/installation

egorized depending on

at might occur at the

gy induced in a system

ategories according EN

-rated meter is suitab

which are not directly
, control signals…

I-rated meter is suita
ments and mono-pha

by means of a plug an

d that the circuit is at

rom a CAT IV-environm

II-rated meter is suita
ments, as well as for

appliances which are

ment, and for measur

oxes, lighting circuits,

V-rated meter is suita

-environments as wel

at for all measuremen
doors (either overhea

s designed in accorda

This implies that certa

DVM831

5

at may contain voltag

circuits with voltages

diode- or continuity m

up to 10A, max. 10s c
a 15 minutes break be

ements on a TV set or
hat high amplitude vo

meter.

arts yourself. Replace

es with the same spe

es at your dealer.

emove test probes pr

vice are forbidden for

odifications to the dev

n category

n the risk and severity

point of test. Transien

m, e.g. caused by ligh

N 61010-1 are:
ble for measurements
y connected to mains

ble for measurements
se appliances which a
d circuits in a normal

t least 10m apart from

ment. E.g. household

able for measurement

measurements on (fix

at least 10m apart fr

rements in or on distr

electric ovens).

able for measuring in

l as on the primary su

nts on equipment for w

d or underground) a C

ance with EN 61010-1

in restrictions in use a

©Velleman nv

ges > 500V

s > 250V

measurements on live

continuous

etween 2

r switching power

oltage pulses at the te

damaged or lost
cifications. Order spar

ior to replacing the

safety reasons.

vice is not covered by

y of transient

nts are short-lived

tning strike on a powe

on protected electron

power, e.g. electronic

s in CAT I-

are connected to the

domestic environmen

m a CAT III- or 20m

appliances, portable

ts in CAT I- and CAT I
xed) mono- or poly-

om of a CAT IV-

ribution level equipme

CAT I-, CAT II- and

upply level.

which the supply cabl
CAT IV meter must b

installation category

apply that are related

v

e

st

re

y

er

nic

cs

nt,

II-

ent

es

be

Advertising