Velleman DVM831 User Manual

Page 8

Advertising
background image

31.03.2010

Voltage meas

Do no

Always
rms. K
measu
to a ci

• Connect the

VΩmA jack

• For DC volta

the range is
appropriate

• For AC volta

the range is
appropriate

• Connect the

• The measur
Notes:

• For DC

test le

• When

althou
norma
stabiliz

Direct curren

Do not
This d
not su

Curren
to 10A
contin
measu

Always
rms. K
measu

For measu

jack and the
500mA/250

For measu

and the blac
10A/220V).

• For DC mea

desired rang

• For DC mea

desired rang

• When the ra

to the appro

• Connect the

• Read the me

surements

ot measure circuits w

s be careful when wor

Keep your fingers behi
urement. Do not touch

rcuit which is being te

e black test lead to the

.

ages, set the selector

s unknown, always set

range.

ages, set the selector

s unknown, always set

range.

e test probes with the
red voltage is shown o

C-measurements: whe

ad, the indicated valu

the mV range is selec

gh the probes are not

al and is caused by the

ze and give a proper m

t measurements

t measure current in c

device is only design

uitable for alternati
nt measurements VΩm

A use the 10A jack. W

uous measurement fo

urements.

s be careful when wor

Keep your fingers beh
urement.

rements up to 200m

e black lead to the CO

V).

rements up to 10A:

ck lead to the COM ja

surements up to 200m

ge.

surements up to 10A,

ge (use the 10A jack)

ange is unknown, alwa
opriate range.

e test probes in series

easured cuurent from

DVM831

8

where voltages > 5

rking with voltages ab

ind the probe barriers

h unused terminals wh

ested.
e COM jack and the re

switch to V

in the d

t the highest possible

switch to V

in the

t the highest possible

circuit under test.

on the display.

en a negative polarity

ue is preceded by a “-

cted, the display may

t connected to a devic
e high input sensitivity
measurement when co

circuits with voltages
ned for DC current m

ng current measure

mA jack max. 200mA

hen measuring curren

ollowed by a 15 minut

rking with voltages ab

ind the probe barriers

mA: connect the red t

OM jack (protected wit

connect the red test
ck (protected with a c

mA, set the selector s

, set the selector switc

).

ays set the highest po

with the circuit.

the display.

©Velleman nv

00V CAT II

bove 60Vdc or 30Vac
s at all times during

hen the meter is linke

ed test lead to the

desired range. When

range and lower to th

desired range. When

range and lower to th

is present at the red

” sign.

show a varying readin

ce or circuit. This is

y. The reading will
onnected to a circuit.

> 250V

measurements; it is

ements.

A; for measurements u

nts up to 10A, max. 1
tes break between 2

bove 60Vdc or 30Vac
s at all times during

est lead to the VΩmA

th a ceramic fuse

lead to the 10A jack

ceramic fuse

witch to A

in the

ch to A

in the

ossible range and lowe

v

ed

he

he

ng

s

up

0s

A

er