10

input impedance

10Mohm

frequency range

50 to 400Hz

maximum input

600Vac

DC current

400µ/4m/400m/10A

basic accuracy

± 1.0% of rdg ± 2 digits for 400µA~4mA range/ ±

1.2% of rdg ± 2 digits for 400mA range / ± 2.0%

of rdg ± 5 digits for 10A range

overload protection 500mA/600V fuse & 10A/600V fuse

AC current

400µ/4m/400m/10A

basic accuracy

± 1.2% of rdg ± 2 digits for 400µA~4mA range/ ±

1.5% of rdg ± 2 digits for 400mA range / ± 2.0%

of rdg ± 5 digits for 10A range

overload protection 500mA/600V fuse & 10A/600V fuse

resistance

400/4k/40k/400k/4M/40M

basic accuracy

± 1.5% of rdg ± 4 digits for 400 ohms range / ±

1.5~2.0% of rdg ± 2 digits for 4k~40M range

overload protection 15 seconds max. 250V on all ranges

capacitance

50.00nF/500.0nF/5.000uF/50.00uF/100.0uF

accuracy

±3.0~5.0% of rdg ± 5~7 digits

frequency

5Hz/50Hz/500Hz/5KHz/50KHz/500KHz/10MHz

basic accuracy

±1.2% of rdg ± 3digits

overload protection 250V AC or DC

maximum display

3999

power supply

9V battery (E-block)

dimensions

170 x 78 x 48mm

weight (with battery) approx. 330g

Use this device with original accessories only. Velleman nv cannot be held

responsible in the event of damage or injury resulted from (incorrect) use

of this device. For more info concerning this product, please visit our

website www.velleman.eu.
The information in this manual is subject to change without prior notice.

© COPYRIGHT NOTICE

This manual is copyrighted. The copyright to this manual is owned by Velleman Components

nv. All worldwide rights reserved. No part of this manual may be copied, reproduced, translated or

reduced to any electronic medium or otherwise without the prior written consent of the copyright

holder.

Advertising