DVM601

22/08/2013

©2008 Velleman

®

Components nv

5

9 light sensor

long life silicon light sensor diode

10 Hz/% button

switch to Hz/% measurement – available when measuring AC/DC

voltage, AC/DC current and Hz/%

11 hold/backlight button

Freeze/unfreeze all values on the display. Press and hold for ±3s to

switch backlight on/off.

12 °C/°F mode button

Switch room temperature reading between °C and °F

13 mode button

Switch between AC and DC current measurement; switch between Ω,

diode and continuity test.

14 range button

Select displayed measurement range manually.

15 REL button

Press to store the current measuring result and start measuring against

this value. Press again to exit relative measurement mode.

16 Non-Contact Voltage (NCV) indicator

turns on when the built-in non-contact AC voltage detector detects AC

voltages

6.

Use

General

When the range of the measured signal is unknown, start measurement

in auto-range mode, and then select range according to indicated value.

The display shows “OL” when the present range limit is exceeded. Select

a higher range to continue measurement.

Do not measure voltages > 600 V or current higher than 500mA (mA/µA

jack [6]) or 10 A (10A jack [7]). Note that the meter can only handle

10A for less than 30 seconds (with 15 minutes cool-down time).

The device will go in sleep mode when no activity is detected for ±30

minutes. Press any button to re-activate.

Sound level measurement

Set the rotary switch [3] to the dBC-position.

Point the microphone [8] towards the sound source for more accurate

measurement. The sound level will be displayed.

Note: strong wind (over 10m/s) will have a negative impact on the

measurement.

Humidity measurement

Set the rotary switch [3] to any position (except OFF).

The relative humidity at the current location is measured ([1]) and the

value is shown on the top line of the LCD [2]. For more accurate results,

let the multimeter acclimatize for ±2h before measuring.