J0

The power capacity for

sending out battery

low alarm report

u8,

percent

15 ~ 100

J1

The power capacity for

power off TR-203

u8,

percent

10 ~ 100

J6

Battery low alarm

report Media

Media type

bit0=SMS

bit1=TCP

bit2=UDP

bit6=Action[0]

bit7=Action[1]

Action=00: report format 0

Action=01: report format 1

Action=10: GPS on

Action=11:

J7

The power capacity for

clear battery low alarm

flag

u8,

percent

10 ~ 100

Battery

J8

Enable/disable TR-203

to automatically power

on when power

capacity is charged to

the capacity of J1

1/0

0=disable

1=enable

O2

Data logger interval

u16, in

seconds

0 ~ 65535

0=disable

Dat

a

logger

OH

Data logger distance

u32, in

meters

0 ~ 4Giga

0=disable

O1

Motion sensor

sensitivity

u16

0 ~ 100

O3

Report format 0

char(32)

Default=SORPZAB27GHKLMN*U!

ON

Report format 1

char(32)

Default=SARN*U!

OG

Enable/ disable data

buffer function

1/0

Default=1

Other setting

O8

Enable/ disable TR-203 1/0

Default=0.