4 motion mode, Pq r – GLOBALSAT TR-203A User Manual

Page 48

Advertising
background image

47

6.4 Motion Mode

Motion mode is an economic report mode. Under motion mode, TR-203 will

report its location with high frequency when TR-203 detects motion

(moving state). When TR-203 is static, it will report its location with low

frequency (static state). It can save the report-transmission fee. Between

the moving state and static state, there is a validation state for TR-203 not

to jump to static state as soon as it does not detect motion. You could set

TR-203 keep in moving state by setting a traveled distance (RE) within a

defined interval (RF).

There are 2 report frequency of motion mode, one is when TR-203 detects

motion, and the other is when TR-203 is static. The behavior is as following:

n

Receive command and then enter motion static mode.

o

When TR-203 detects motion, it will enter motion moving mode and

send “static to moving” report.

p

Motion Moving Report.

q

When TR-203 is static, it will send “moving to static” report and then

return to the motion static mode.

r

Re-start timer for motion static interval.

s

Motion Static Report.

n

o

p

q

r

Time

R0 (Static interval)

R1 (Moving interval)

(Static Report)

(Moving Report)

(Static to Moving Report)

(Moving to Static Report)

s

Note of Traveled Distance:

You can also set a traveled distance, and then TR-203 will report by the

combination of report interval and traveled distance.

For example, the report interval is 60 seconds, the traveled distance is 800

meters, TR-203 sends 1 report at 10:00:00, and then it detects the traveled

distance is over 800 meters at 10:00:50, it will send out one report and

re-start to count the report interval and the traveled distance. The next report

will be sent out at 10:01:50 or when the traveled distance is over 800 meters.

Advertising