20

96454 v.9.0

NotE: the Banks Six-Gun tuner for

the Ford 7.3L Power Stroke engine

increases the fuel pressure to increase

performance. If the fuel system on your

Ford 7.3L Power Stroke engine cannot

supply the demanded fuel then an

engine code will be set. the engine code

set may be the P1211- (Injector Control

Pressure is different than expected). If

this occurs to you while driving then

select a lower Six-Gun power level and

continue to lower the power level until

you no longer set the engine code. the

code clears itself after several ignition

cycles.
The Six-Gun Diesel Tuner is equipped

with self-diagnosing features that

automatically check for proper sensor

and module operation. Error codes

that your module may display, either

upon startup or after accessing the

Diagnostics submenu, are listed below.

Section 4:

TROUBLESHOOTING

Table 2

Error Code

Code Description

Course of Action

BST ERR1

The Six-Gun module
has detected a fault in
the Manifold Absolute
Pressure (MAP) input
circuit.

The listed error code(s) will occur when the
Six-Gun module fails to receive any signal from
the associated sensor, or receives an input
signal from the sensor that is out of the normal
operating range.

Turn the vehicle and ignition completely off,
check the Six-Gun harness connections at the
sensor in question to ensure that they are fully
engaged. Also check the 2- and 6-pin connectors
at the back of the Six-Gun module to ensure
that they are properly engaged. After checking
all connections, restart the vehicle – if the Six-
Gun module continues to display the same error
message, please contact Banks Technical Service

ICP ERR2

The Six-Gun module
has detected a fault in
the Injection control
Pressure (IcP) input
circuit.

EGT ERR3

The Six-Gun module
has detected a fault
in the Exhaust Gas
Temperature (EGT)
input circuit.

BSTO ERR4

The Six-Gun module
has detected a fault in
the Manifold Absolute
Pressure (MAP) output
circuit.

The listed output error(s) will be displayed when
the Six-Gun module detects a problem with the
associated output signal.

Turn the vehicle and ignition completely off,
check the Six-Gun harness connections at the
sensor in question to ensure that they are fully
engaged. Also check the 6-pin connector at the
back of the Six-Gun module to ensure that it is
properly engaged. After checking all connections,
restart the vehicle – if the Six-Gun module
continues to display the same error message,
please contact Banks Technical Service.

ICPO ERR5

The Six-Gun module
has detected a fault in
the Injection control
Pressure (IcP) output
circuit.

INT ERR6

The Six-Gun module has
detected an internal
(module) error.

Turn the vehicle completely off then restart it – if
the error is still present contact Banks Technical
Service.