96506 v.8.0

Table 1 Banks EconoMind Diagnostic Codes

Code

Event

Course of action

1,1

Fuel Rail Pressure (FPR) Input

Voltage Out of Range

Turn ignition OFF and check the 24-Pin and 38-Pin connectors. Turn
ignition back ON and re-check for presence of code. If problem persists,
call Gale Banks Engineering Tech Support.

1,2

Manifold Absolute Pressure
(MAP) Input Voltage Out of

Range.

Turn ignition OFF and check the 24-Pin and 38-Pin connectors.
Turn Ignition back ON and re-check for presence of code. If problem
persists, call Gale Banks Engineering Tech Support.

1,3

EconoMind Switch Input Value

Out of Range

Turn ignition OFF and make sure either Banks PowerPDA orEconoMind
switch is connected to EconoMind tuner. If EconoMind switch is
connected (no Banks PowerPDA), check 2-pin connection on tuner’s
in-cab cable. Turn ignition back ON and re-check for presence of code. If
problem persists, call Gale Banks Engineering Tech Support.

1,4

(LB7) Barometric Pressure Input

Voltage Out of Range

Turn ignition OFF and check the 24-Pin and 38-Pin connectors. Turn
ignition back ON and re-check for presence of code. If problem persists,
call Gale Banks Engineering Tech Support.

(LLY) Barometric Pressure cAN

Signal Not Available

2,1

Fuel Rail Pressure (FPR) Output

voltage Out of Range.

Turn ignition OFF and check the 24-Pin and 38-Pin connectors.
Turn ignition back ON and re-check for presence of code.
If problem persists, call Gale Banks Engineering Tech Support.

2,2

Manifold Absolute Pressure

(MAP) Output Voltage Out of

Range.

Turn ignition OFF and check the 24-Pin and 38-Pin connectors.
Turn ignition back ON and re-check for presence of code.
If problem persists, call Gale Banks Engineering Tech Support.

2,3

Exhaust Gas Temperature (EGT)

Sensor Open circuit.

Turn ignition OFF and check both thermocouple ring-terminal
connections. Turn ignition back ON and re-check for presence of code. If
problem persists, call Gale Banks Engineering Tech Support.

2,4

OBD Signal Malfunction

Turn ignition OFF and check OBD connector and cable. Turn ignition back
ON and re-check for presence of code. If problem persists, call Gale Banks

Engineering Tech Support.

3,1

crankshaft Position (cKP)

Strand Fault or Internal Module

Malfunction.

Turn ignition OFF and check the 24-Pin and 38-Pin connectors.
Turn ignition back ON and re-check for presence of code.
If problem persists, call Gale Banks Engineering Tech Support.

3,2

Power Up Error or Internal

Module Malfunction

Turn ignition OFF and check the 24-Pin and 38 Pin connectors. Turn
ignition back ON and re-check for presence of code.
If problem persists call Gale Banks Engineering Tech Support.

3,3

Low Battery Voltage or Internal

Module Malfunction.

Turn ignition OFF and check the 24-Pin and 38-Pin connectors. Turn
ignition back ON and re-check for presence of code.
If problem persists, call Gale Banks Engineering Tech Support.

3,4

cAN communications Error with

Vehicle.

Turn ignition OFF and check the 24-Pin and 38-Pin connectors.
Turn ignition back ON and re-check for presence of code.
If problem persists, call Gale Banks Engineering Tech Support.

4,1

Injection control Signal Fault or

Internal Module Malfunction

Turn ignition OFF and check the 24-Pin and 38-Pin connectors.
Turn ignition back ON and re-check for presence of code.

If problem persists, call Gale Banks Engineering Tech Support.

4,2

Transmission slippage Detected

Transmission is slipping excessively. Code will automatically clear once

transmission stops slipping (repaired).

5,1

Internal Module Malfunction

Turn ignition off. Turn ignition back ON and re-check for presence of code.

If problem persists, call Gale Banks Engineering Tech Support.

Advertising