Center collar placement, Chapter 7: roof assembly – Grain Systems Tanks PNEG-4075 User Manual
Page 96
9. Repeat this procedure for the remaining three center collar channel clips (M).
Figure 7-20 Installing center collar channel clips
J
1/2 in. flange nut (S-10253)
M
Center collar channel clip (CTR-0209)
K
Row of three holes
N
Center collar channel clip (CTR-0083)
L
1/2 x 1-3/4 in. flange bolt (S-10252)
10.Tighten all of the hardware to the recommended torque specifications, see
Center Collar Placement
The following figure gives the approximate height needed to install the center collar.
With two sidewall rings in place, position the center collar at the height specified, measuring from the
bottom of the center collar to the foundation as shown. If additional rings are required for construction pur-
poses, add 32 in. for each additional ring.
NOTE: It is better to set the center collar a little too high. Do not set the center collar too low.
96
Pneg-4075 75 Ft Diameter 40-Series Bin