SERIES 2000 HEATER SERVICE

All Airstream heaters are con-
structed of durable weather-resis-
tant materials, so a minimum
amount of service should be re-
quired; however before the unit is
started for the first time each sea-
son there are a few items that need
to be checked out. All damaged
parts should be repaired or re-
placed.

1. Disconnect and lock out power

to fan and heater. Open control
box lid and inspect all compo-
nents for moisture, vibration or
rodent damage. Inspect and
tighten all loose terminal con-
nections. Replace any damaged
wiring.

2. Remove burner orifice tube and

inspect for dirt or foreign mate-
rial. Clean out if necessary.

3. Inspect burner for wear or for-

eign material in any of the ports.
Clean or replace parts if necessary.

4. Inspect the spark plug and flame

probe for corrosion and dam-
age. Clean or replace if necessary.

The Series 2000 control box.