Chapter 7: roof assembly – Grain Systems Tanks PNEG-4090A User Manual

Page 96

Advertising
background image

Chapter 7: Roof Assembly

Figure 7-19 Purlin location 1

A

Left-hand lower roof rafter (CTR-0436 and CTR-
0438)

H

Purlin (CTR-0430)

B

1/2 x 1-3/4 in. flange bolt (S-10252)

I

1/2 in. flange nut (S-10253)

C

Right-hand lower roof rafter (CTR-0436 and
CTR-0438)

J

Top X-brace (CTR-0042)

D

Right purlin clip (CTR-0100)

K

Bottom X-brace (CTR-0042)

E

Left purlin clip (CTR-0099)

L

1/2 x 1-3/4 in. flange bolt (S-10252)

F

1/2 x 1-3/4 in. flange bolt (S-10252)

M

1/2 in. flange nut (S-10253)

G

1/2 in. flange nut (S-10253)

96

Pneg-4090A 90 Ft Diameter 40-Series Bin

Advertising