Dr ying rates/shelled corn, Top dry batch series, Series 2000 top dry heater control – Grain Systems PNEG-743 User Manual

Page 12

Advertising
background image

13

Series 2000 Top Dry Heater Control

DR YING RATES/SHELLED CORN

Top Dry Batch Series

Fan and heater

unit(s)

10-12 H.P.

36" fan

3.5 million

BTU/HR

10-16 H.P.

36" fan

4.5 million

BTU/HR

10-16 H.P.

42" fan

5.75 million

BTU/HR

20 H.P.

42" fan

6.75 million

BTU/HR

30 H.P.

42" fan

8.75 million

BTU/HR

40 H.P.

42" fan

10.25 million

BTU/HR

*Indicates insufficient burner BTUs.
Estimated at ambiant temperature 45 degrees F, relative humidity 65%.
Use only as a guide, conditions will vary capacities.
1/4 cfm cooling.

Plenum

temperature

(fahrenheit)

140

160

180

140

160

180

140

160

180

140

160

180

140

160

180

140

160

180

Moisture

removal

%

5%

10%
15%

5%

10%
15%

5%

10%
15%

5%

10%
15%

5%

10%
15%

5%

10%
15%

5%

10%
15%

5%

10%
15%

5%

10%
15%

5%

10%
15%

5%

10%
15%

5%

10%
15%

5%

10%
15%

5%

10%
15%

5%

10%
15%

5%

10%
15%

5%

10%
15%

5%

10%
15%

30' diameter

1 fan

Batch

time

hours

3.8
6.0
9.5
3.2
4.9
8.0

*
*
*

3.3
5.1
8.2
2.8
4.4
6.8

*
*
*

2.7
4.2
6.7
2.2
3.5
5.6
1.8
2.7
4.4
2.5
3.9
6.4
2.1
3.3
5.3
1.6
2.6
4.1
2.4
3.6
5.9
2.0
3.1
4.9
1.5
2.4
3.9
2.1
3.3
5.2
1.8
2.7
4.4
1.4
2.1
3.4

BU/HR

396
251
157
473
299
187

*
*
*

461
292
182
550
348
218

*
*
*

562
356
222
670
425
265
858
543
339
599
379
237
715
453
283
915
580
362
638
405
253
762
482
302
975
618
386
726
460
287
867
549
343

1,110

702
439

30' diameter

2 fan

Batch

time

hours

2.4
3.8
6.0
2.0
3.2
5.1
1.5
2.5
3.9
1.9
3.3
5.2
1.8
2.7
4.4
1.4
2.1
3.4

BU/HR

629
398
249
751
475
297
961
609
380
728
461
288
869
550
344

1,112

704
440

36' diameter

1 fan

Batch

time

hours

4.1
6.5

10.4

3.4
5.4
8.7

*
*
*

3.3
5.2
8.4
2.8
4.4
7.1

*
*
*

3.2
5.1
8.0
2.7
4.2
6.7

*
*
*

2.9
4.7
7.5
2.5
4.0
6.4
2.0
3.1
4.9
2.7
4.2
6.7
2.2
3.5
5.6
1.8
2.7
4.4

BU/HR

521
330
206
622
394
246

*
*
*

650
411
257
775
491
306

*
*
*

674
427
267
805
510
318

*
*
*

717
454
284
856
542
338

1,095

694
433
810
513
320
966
612
382

1,236

783
489

36' diameter

2 fan

Batch

time

hours

2.9
4.6
7.3
2.5
3.9
6.1

*
*
*

2.6
4.0
6.5
2.1
3.4
5.4
1.6
2.7
4.2
2.1
3.3
5.3
1.8
2.8
4.5
1.4
2.2
3.5
2.0
3.2
5.2
1.8
2.7
4.4
1.3
2.1
3.4
1.9
2.9
4.7
1.5
2.5
4.0
1.3
2.0
3.2

BU/HR

741
469
293
884
560
350

*
*
*

841
533
333

1,004

636
397

1,284

814
508

1,022

647
404

1,219

772
482

1,560

988
617

1,058

670
418

1,262

799
499

1,615
1,023

639

1,142

723
452

1,363

863
539

1,744
1,105

690