14

Series 2000 Top Dry Heater Control

FACTOR Y CONFIGURATION

Configuration Dip

Switches (Normally Done

At Gsi)

Top Dry remote
display at the bot-
tom-dip switch 1 &
6 on/all others off.

Top Dry master
with a remote dis-
play at the bottom-
dip switch 6 & 7 on/
all others off.

These switches are used to con-
figure the heater control for vari-
ous types of heaters.

Top Dry 2nd fan
heater-dip switch 2
& 6 on/all others off.

Top Dry 3rd fan
heater-dip switch 1,
2 & 6 on/all others
off.

Top Dry master
with a remote dis-
play at the bottom
and 2 slave fan
heater-dip switch 6,
7 & 8 on/all others
off.

Top Dry master
with a remote dis-
play at the bottom
and one slave fan
heater-dip switch 6
& 8 on/all others off.

Multiple heaters connected to-
gether through the serial link.

Top Dry stand
alone with no re-
mote display at the
bottom-dip switch 6
on/all others off.

The backside of the control board, showing the dip switch placement.