PNEG-1722 Series II Sweep Protected Cord Slip Ring Sump

7. Troubleshooting

Problem

Possible Cause

Solution

Sweep will not run.

1. Power cords may be unplugged.

1. Plug in the power cords.

2. Foot switch may not be actuated.

2. Make sure the foot switch is depressed

and the switch is operating properly.

3. Overloads may be tripped.

3. Reset the overloads.

4. The collector ring may not be making

good connections.

4a. Check the collector ring terminals for

proper contact.

4b. Make sure the springs have correct

tension according to the owner’s manual.

Intermittent signal
or loss of signal.

1. Brush wear.

1. Verify brush wear per section.

2. Spring pressure.

2. Check spring pressure per section.

3. Dirty contact surface.

3. Check contact surfaces for cleanness.

(Ring polishing kit available.)

4. Bad springs.

4. Visually check for spring fit and function.

Adjust or replace as necessary.

5. Short in wire.

5. Check core wiring for short circuit.