Grain Systems Bin Accessories PNEG-1924 User Manual
Page 10
105 ft Diameter Bin
Figure 1-9 A-frame installation sequence and temperature cable locations for 105 ft diameter bin
A
5 ft radius location (center collar)
C
28.3 ft radius location
B
10.3 ft radius location
D
42.4 ft radius location
Table 1-6 Starting lengths for temperature cables for 105 ft diameter bins
Length from the center collar
None
Length from 10.3 ft diameter location
288.3 in. (73.22 m)
Length from 28.3 ft diameter location
160.1 in. (40.67 m)
Length from 42.4 ft diameter location
62.5 in. (15.88 m)
The temperature cable lengths in the chart above are the distances from where the temperature cable
attaches to the rafter or the center collar to the top ring. To calculate the correct temperature cable length,
add 32 inches for each bin ring to the starting length. Temperature cables must terminate above any
unload equipment and be secured in place with twine. DO NOT allow cables to become tangled in unload
equipment.
10