Grain Systems Bin Accessories PNEG-1924 User Manual

Page 6

Advertising
background image

72 ft Diameter Bin

Figure 1-5 A-frame installation sequence and temperature cable locations for 72 ft diameter bin

A

9.3 ft radius location

B

26 ft radius location

Table 1-2 Starting lengths for temperature cables for 72 ft diameter bins

Length from the center collar

None

Length from 9.3 ft diameter location

179.2 in. (14.76 m)

Length from 26 ft diameter location

59.6 in. (15.14 m)

The temperature cable lengths in the chart above are the distances from where the temperature cable
attaches to the rafter or the center collar to the top ring. To calculate the correct temperature cable length,
add 32 inches for each bin ring to the starting length. Temperature cables must terminate above any
unload equipment and be secured in place with twine. DO NOT allow cables to become tangled in unload
equipment.

6

Pneg-1924

Advertising