Chapter 7: roof assembly – Grain Systems Tanks PNEG-4054 User Manual

Page 105

Advertising
background image

Chapter 7: Roof Assembly

1. Attach the two roof panel clips (B) to the left-hand roof rafter (A), and install two flange bolts (D) and

two flange nuts (E) securing the roof panel clips to the left-hand roof rafter.

2. Attach the third roof panel clip (B) to the right-hand roof rafter (A), and install two flange bolts (D) and

two flange nuts (E) securing the roof panel clips to the right-hand roof rafter.

NOTE: Ensure that the orientation of the roof panel clip is correct, roof panel holes facing the roof

and the notch in the roof panel clip is facing the right-hand roof rafter.

3. Tighten all hardware to the recommended torque specifications only after the roof panels are

installed. See

Bolt Torque Specifications, page 29

.

Figure 7-23 Roof panel clip

A

Left-hand roof rafter (CTR-0405)

D

7/16 x 1-1/4 in. flange bolt (S-10250)

B

Roof panel clip (CTR-0410)

E

7/16 in. flange nut (S-10251)

C

Right-hand roof rafter (CTR-0405)

After You Finish

Repeat this procedure for the remaining roof panel clips.

Pneg-4054 54 Ft Diameter 40-Series Bin

105