1. Attach the two roof panel clips (B) to the left-hand roof rafter (A), and install two flange bolts (D) and
two flange nuts (E) securing the roof panel clips to the left-hand roof rafter.
2. Attach the third roof panel clip (B) to the right-hand roof rafter (A), and install two flange bolts (D) and
two flange nuts (E) securing the roof panel clips to the right-hand roof rafter.
NOTE: Ensure that the orientation of the roof panel clip is correct, roof panel holes facing the roof
and the notch in the roof panel clip is facing the right-hand roof rafter.
3. Tighten all hardware to the recommended torque specifications only after the roof panels are
installed. See
Bolt Torque Specifications, page 29
.
Figure 7-23 Roof panel clip
A
Left-hand roof rafter (CTR-0405)
D
7/16 x 1-1/4 in. flange bolt (S-10250)
B
Roof panel clip (CTR-0410)
E
7/16 in. flange nut (S-10251)
C
Right-hand roof rafter (CTR-0405)
After You Finish
Repeat this procedure for the remaining roof panel clips.
Pneg-4054 54 Ft Diameter 40-Series Bin