Center collar placement – Grain Systems Tanks PNEG-4054 User Manual

Page 99

Advertising
background image

Chapter 7: Roof Assembly

Center Collar Placement

The following figure gives the approximate height needed to install the center collar.

With two sidewall rings in place, position the center collar at the height specified, measuring from the
bottom of the center collar to the foundation as shown. If additional rings are required for construction pur-
poses, add 32 in. for each additional ring.

NOTE: It is better to set the center collar a little too high. Do not set the center collar too low.

Figure 7-18 Center collar placement

A

224.924 in. (574.31 cm) from foundation to bottom of center collar on 54 ft diameter bin

Pneg-4054 54 Ft Diameter 40-Series Bin

99