Series 2000 Vane Axial Heater

HEATER INSTALLATION

Standard electrical safety prac-

tices and codes should be used

when working with a heater.

Refer to the National Electric

Code Standard Handbook by

the National Fire Protection

Association. A qualified elec-

trician should make all wiring

installations.

IMPORTANT! Do not use pro-

pane tanks that have previ-

ously been used for ammonia

unless they have been purged

according to procedures of the

National L.P. Association.

Fuel supply system must

comply with local codes for L.P.

gas installation.

1. Propane vapor models are designed to run di-

rectly off of a supply tank or from a separate

3. After installation is complete check all connec-

tions for leaks. DO NOT USE FLAME FOR
LEAK TESTING.

Liquid Propane Models

Natural Gas Models

Propane Vapor Models

ALWAYS DISCONNECT

AND LOCK OUT

POWER

BEFORE WORKING ON

OR AROUND HEATER

1. Natural gas models are designed to run directly

off of a supply tank or from a separate
external vaporizer.

2. Run proper size line (see specification on page 7)

to pipetrain on heater. Have a qualified gas
service person inspect installation to be sure ev-
erything is installed according to local codes
and ordinances.

3. After installation is complete check all connec-

tions for leaks. DO NOT USE FLAME FOR
LEAK TESTING.

3. After installation is complete check all connec-

tions for leaks with liquid detergent or compa-
rable. Wear rubber gloves and eye protection.
Avoid contact with liquid propane. DO NOT
USE FLAME FOR LEAK TESTING.

1. L.P. models are designed to run on liquid pro

pane with liquid draw from the propane tank.
Avoid using propane supply tanks that have been
used for vapor draw for long periods of time.
When using liquid draw systems any moisture
that may be present in tank or lines may freeze
when system is used in cold weather. To avoid
this situation, purge the system with methanol.

2. Run proper size line (see specification on page

7) to liquid pipetrain on heater. Have a qualified
gas service person inspect installation to be sure
that everything is installed according to local
codes and ordinances.

Fuel Connection

external vaporizer.

2. Run proper size line (see specifications on page

7) to pipetrain on heater. Have a qualified gas
service person inspect installation to be sure that
everything is installed according to local codes
and ordinances.