PNEG-581 Deluxe Vane Axial Heater

3. Heater Installation

Bin Configuration

Figure 3C

IMPORTANT: When mounting two (2) heaters on a bin it is imperative that they be situated as in

Figure 3C

. Plenum thermostat must be to the right of master heater and master heater

must be to the right of slave heater.

Transition High-Limit Installation

1. Mark location on transition one (1) foot up from the bottom (entrance collar) and centered in

the transition.

2. Drill or knock out 7/8" diameter hole on marked location.

3. Install transition High-Limit using supplied self-drilling screws.

Figure 3D The transition connecting the Vane Axial Heater to the bin