16
PNEG-581 Deluxe Vane Axial Heater
3. Heater Installation
Bin Configuration
Figure 3C
IMPORTANT: When mounting two (2) heaters on a bin it is imperative that they be situated as in
. Plenum thermostat must be to the right of master heater and master heater
must be to the right of slave heater.
Transition High-Limit Installation
1. Mark location on transition one (1) foot up from the bottom (entrance collar) and centered in
the transition.
2. Drill or knock out 7/8" diameter hole on marked location.
3. Install transition High-Limit using supplied self-drilling screws.
Figure 3D The transition connecting the Vane Axial Heater to the bin
with the plenum sensor in place.