BTUs per Gauge Pressure (PSI) Natural Gas Models (Approximate)

High-Temperature

Low-Temperature

Gauge Pressure (PSI) Required to Maintain Temperature (Approximate)

(High-Temperature Units Only)

Diameter

Operating Pressure (PSI)

1

2

3

4

5

6

7

18"

454180

644780

787970

909260

1016880

1115380

1204750

24"

710450

1006850

1231200

1419980

1587790

1741920

1881456

26"

938450

1331520

1627920

1876896

2099420

2302800

2487940

28"

1022350

1450080

1772020

2043790

2285470

2507090

2708640

Diameter

Operating Pressure (PSI)

1

2

3

4

5

6

7

18"

144100

205200

250800

289100

322850

353860

383040

24-28"

177840

251710

308260

355680

397632

435936

470590

Fan Model

Static Pressure

Heat Rise °F

60

80

100

120

140

160

180

3 HP-18"

1"

1

1

2

2

3

3

4

2"

1

1

1

1

2

2

3

3"

Low-Temperature Low-Temperature

1

1

1

1

31

7 HP-24"

1"

1

2

2

3

4

5

6

2"

1

1

1

2

2

3

4

3"

Low-Temperature Low-Temperature

1

1

1

1

2

4"

Low-Temperature Low-Temperature Low-Temperature

1

1

1

1

10 HP-24"

1"

2

2

4

5

6

7

8

2"

1

2

3

3

4

6

7

3"

1

1

1

2

2

3

4

4"

Low-Temperature

1

1

1

1

2

2

15 HP-26"

1"

1

2

2

3

4

5

7

2"

1

1

2

3

3

4

5

3"

1

1

2

2

3

3

4

4"

1

1

1

1

2

2

3

5"

Low-Temperature Low-Temperature

1

1

1

1

2

15 HP-28"

1"

1

2

3

4

5

7

8

2"

1

2

2

3

4

5

6

3"

1

1

2

2

3

4

5

4"

1

1

1

1

2

2

3

5"

Low-Temperature Low-Temperature

1

1

1

2

2

Advertising