background image

5. Installation

PNEG-1776 Deluxe Downwind Heater - Canadian

17

Bin Configuration

Figure 5C

IMPORTANT: When mounting two (2) heaters on a bin it is imperative that they be situated as shown in

Figure 5C

. Plenum thermostat must be to the right of master heater and master heater must

be to the right of slave heater.

Plenum Thermostat Mounting

The plenum thermostat must be ordered separately from the heater unit.

1. Follow installation instructions provided with the thermostat assembly.

2. Position the housing so that the bolt flanges are vertical and the cord exits the housing from the

bottom. Mark position.

3. Use 6 (4.00") or 8 (2.66") self-drilling screws to mount the housing to the bin sidewall. DO NOT

TIGHTEN COMPLETELY. Insert corrugation seal into gap between housing and sidewall.
Tighten screws.

4. Caulk between the housing and the sidewall to seal.

Heater control device (thermostat or humidistat) is required for heater warranty on all heaters.

CAUTION

Thermostat must be installed to operate as plenum high-limit safety.