Series 2000 Autoflow Operation

Series 2000 Autoflow Operation

Series 2000 Autoflow Operation

Series 2000 Autoflow Operation

Series 2000 Autoflow Operation

Normal Start Up

When the dryer is started with grain in the drying
chamber that has already been partially dried, the
dryer can be started without making any adjustments to
time or temperature; however, the moisture of the grain
should be checked after the fourth dump.

Last Fill

1) Stop the dryer when all the wet grain has been
loaded into the drying chamber and turn off the mois-
ture control switch.

28) Any time a change is made to the grain tempera-
ture setpoint the dryer must dump four times before the
full effect of the change will be made on the moisture
of the grain.

START UP PROCEDURE

START UP PROCEDURE

START UP PROCEDURE

START UP PROCEDURE

START UP PROCEDURE

2) Set the time on the dry timer for twice the recom-
mended amount using the following charts for the
specific bin size, fan and heater size, drying tempera-
ture and grain input moisture content.

3) Push the reset button.

4) Turn the dry and hold switch to the “on” position.

5) Turn the load auger switch to the “off” position.

5) Press the start switch.

5) When the dryer shuts down install the fan inlet
cover(s).

6) Let the aeration fan cool in the top and store, or
manually dump into the storage chamber.