Placing the reinforcement – Grain Systems Tanks PNEG-1093 User Manual
Page 17

5. Foundation
PNEG-1093 2.66" Corrugation Unstiffened Bin
17
Placing the Reinforcement
1. Once the forms and trench have been prepared, begin the placement of reinforcement rods and
mesh at various levels in the foundation’s footing. (See the appropriate charts and drawings for the
bin to determine requirements and positions of the reinforcement
) Reinforcement
rods should be properly lapped by wiring.
2. Next, place a minimum of 2" of compacted sand on the inside section of the foundation to provide a
good base for the concrete and protect against rodents.
3. The sand should then be covered with 4 mil polyethylene plastic which will act as a moisture barrier.
4. Two (2) layers of 6" x 6" wire mesh should then be added to the entire area of the foundation slab or
the entire foundation for monolithic systems to complete the preparation of the bin’s foundation.
Figure 5C Octagon Form
* All concrete to have a minimum compressive
strength of 3000 PSI at 28 days.
2" x 8" Forms
6" x 6" Wire mesh
Footing trench
Foundation line