Standard heater - second heater installation – Grain Systems PNEG-1775 User Manual

Page 15

Advertising
background image

5. Installation

PNEG-1775 Vane Axial Heater - Canadian

15

Standard Heater - Second Heater Installation

Two (2) standard heaters may be connected to one grain drying system and wired so they cycle together.
One of the heaters should have a thermostat connected to it as per the installation instructions. That
heater will be referred to as the primary. The other heater (without the thermostat) will be referred to as
the secondary.

1. Install relay base (TD-100283) in primary heater control box.

2. Connect wire between terminal 13 on relay base to terminal 5 on terminal strip in primary heater.

3. Connect wire between terminal 14 on relay base to terminal 6 on terminal strip in primary heater.

4. Run two (2) wires (18 gauge) between primary and secondary heater.

5. Connect wires to terminals 5 and 9 (points A and B) on relay base in primary heater.

6. Connect wire from terminal 9 in primary to (point F) in secondary unit.

7. Connect wire from terminal 5 in primary to (point G) in secondary unit.

8. Install relay (TD-100282) in relay base.

Follow these additional steps for HIGH-LOW units.

1. Install relay base (TD-100283) in master heater control box.

2. Connect wire between terminal 13 on relay base to green wire from HIGH-LOW thermostat in master

unit. Do not disconnect other wires from green wire 3. Connect wire between terminal 14 on relay
base to terminal 14 on other relay base in master heater.

3. Run two (2) wires (18 gauge) between master and slave heater.

4. Connect wires to terminals 5 and 9 (points A and B) on relay base in master heater.

5. Connect wire from terminal 9 in master to terminal 6 (point G) in slave unit.

6. Connect wire from terminal 5 in master to cycle solenoid and red light in slave unit. Do not connect

wire to side of cycle solenoid and light that are connected to terminal.

Figure 5B CSA Heater - Second Heater Relay Connection

Advertising