Problem possible cause solution – Grain Systems Bucket Elevtors, Conveyors, Series II Sweeps PNEG-1418 User Manual

Page 13

Advertising
background image

PNEG 1418  Sales Information Package 

13 

4.  DRIVELINE SHEAR BOLT 

SHEARS FREQUENTLY. 

A1.  Reduce the flow rate of grain into 

the ground hopper. 

A.  Grain may be flowing too quickly 

into the ground hopper. 

B.  The discharge of grain from the 

main auger may be restricted. 

B1.  Inspect  auger  intake  and  dis­ 

charge areas for damage. 

Problem 

Possible Cause 

Solution 

1.  THE AUGER IS 

VIBRATING. 

A.   Damage can occur to the auger 

flighting,  causing  noise. 
Damage usually is caused from 
foreign   materia l  be ing  run 
through the auger. 

A1.  It may be necessary to remove 

the flighting for inspection. 

2.  CAPACITY IS TOO LOW. 

A.  There may not be enough grain 

reaching the auger. 

A1.  Make  sure  the  intake  has  not 

bridged  over,  restricting  flow. 
The flighting at the intake should 
be covered with grain for maxi­ 
mum capacity. 

B.  The auger is moving too slowly. 

B1.  Check  the  auger  speed.  Low 

capacity will result from speeds 
slower than  recommended. 

3.  THE AUGER PLUGS. 

A.    The  auger  may  be  "jamming" 

because  too  much  grain  is 
reaching the auger. 

B.  The grain may be wet. 

B1.    If  wet  grain  or  other  hard­to­ 

move material is being augered, 
reduce  the  amount  of  grain 
being fed into the swing­away 
hopper. 

C.  The auger may be jammed with 

foreign material. 

C1.  Remove any foreign material 

in the auger. 

D.  The  discharge  end  may  be 

plugged. 

D1. Unplug any plugs at the dis­ 

charge end of the auger. 

A1. Decrease the amount of grain the 

auger is gathering.

Advertising